SECTION 10170

SOLID PLASTIC TOILET COMPARTMENTS

FLOOR MOUNTED OVERHEAD BRACED

Aluminum CWB and Continuous hinge

 

 

PART I- GENERAL

 

1.01   SUMMARY

 

A.    Documents affecting work of this Section include, but are not necessarily limited to, General Conditions, Supplementary Conditions, Special Conditions and Division 1.

 

B.     Section Includes:

        1.        Solid plastic toilet compartments, floor mounted overhead braced.             

 2.        Solid plastic urinal screens, wall hung.

 

1.02 REFERENCES

 

A.   International Conference of Building Officials.

 

1.            AC150, Acceptance Criteria For Plastic Partitions Used in Public Restrooms

 

2.            UBC Chapter 52

 

B.     American Society for Testing and Materials. ( ASTM )

 

1.     ASTM A167 - Stainless and Heat-Resisting Chromium-Nickel Steel Plate,   Sheet, and Strip.

2.     ASTM B221 - Aluminum Alloy Extruded Bars, Rods, Wire. Shapes and Tubes.

3.     ASTM D2843 - Smoke Density

        ASTM D 635-81 - Rate Of Burn

               ASTM D 1929 -77 - Self ignition Properties

 

C.    California Code of Regulations - Title 24.

 

1.     CAS/CAR - California Accessibility Statutes/ California Accessibility Regulations, Books 1 and 2, May, 1994.

 

D.      Americans with Disabilities Act. 1.       ADA-Title II.

 

 

1.03 QUALITY ASSURANCE

 

1.     Manufacturers; Comtec Industries, as represented by Service Oriented Sales, Ph (877) 767 4636, Fax (877) 767 3227, or approved equal by architect.

 

 

 

 

 

1.04   SUBMITTALS

 

A.    Submit under provisions of Section 01300.

 

B.    Shop Drawings: Indicate partition plan, elevation views, dimensions, and panel and door sizes, details of wall, floor supports, and door swings.

 

            C.    Product Data: Provide data on panel construction, hardware, and accessories.

 

D.    Samples: Submit sample of partition panels, illustrating panel finish, color, and sheen and quarter scale model if requested by architect.

 

E.    Provide a sample of each type of hardware, if requested by architect.

 

 

1.05  REGULATORY REQUIREMENTS

 

A.    Comply with CAS/CAR and ADA for accessibility for the physically disabled.

 

            B.    ASTM Test Standards ASTM Results

                            

Test                              Standard                  Results                       ASTM Method

            Self Ignition                    650 F.                     700 F.                           D 1929-77

            Rate of Burn               2.0 cm/min.            1.29 cm/min.                     D 635-81    

            Smoke Density                <75                         13.9                              D 2843

 

1.06 LEED Environmental Requirements

 

Provide Local source materials ( within 500 miles )

1.      Submit required Documentation for LEED Credit on Local/Regional Materials; each submittal shall include the following:

a.       Cost of Materials ( exclude Labor and Transportation )

b.      Air Miles from fabrication point to job site.

2.      See LEED Record Document and required attachments at end of Section 01700

 

Provide product with highest possible recycled content.

1.      Required Documentation for LEED Credit on Recycled content; each submittal     shall include the following:

a.       Cost of materials ( exclude labor and transportation ).

b.      Recycled content ( % post consumer, % post industrial, and total ).

2.      See LEED Record Document and required attachments at end of Section 01700.

 

 

 

1.07 FIELD MEASUREMENTS

 

A.   Verify that field measurements are as indicated on shop drawings.

 

 

 

1.08 COORDINATION

 

A. Coordinate placement of backing in walls. Backing by others.

 

1.09 EXTENDED WARRANTY

 

A.    Provide manufacturer's standard 15 year warranty, to include breakage, corrosion or delamination of installed plastic components, and hardware. Defective components shall be replaced. Labor for reinstallation not included.

 

 

 

PART 2 - PRODUCTS

 

2.01   SYSTEMS

          

           A.    Floor Mounted Overhead Braced, Poly-blend System using, Aluminum Continuous Hinge and Aluminum Continuous Wall and Panel Bracket features.

 

 

2.02   MATERIALS

 

A.    Solid Plastic: High density polyethylene (HDPE) containing 30% recycled resin, manufactured under high pressure forming a single component section that is waterproof, nonabsorbent, with a self-lubricating surface resistant to marking with writing utensils.

 

 

2.03   COMPONENTS

 

A.    Pilaster Shoe: Stainless Steel.

 

B.    Head Rail: ASTM B221; aluminum extrusion, 6364-T5 alloy with clear

        Anodized finish and anti-grip configuration, minimum 1.188 lbs. per lineal foot.

 

C.    Attachments, Screws, and Bolts: ASTM A167; Type 304 stainless steel.

 

D.    Through Bolts and Nuts: Type 304 stainless steel, Anti theft type.

 

E.     Hardware:

 

1.    Hinges: Continuous Aluminum type with theft proof screws and through bolts at top and bottom.

 

2.   Door latch Housing: Aluminum extrusion with clear anodized finish, surface mounted and fastened to door with Type 304 stainless steel vandal resistant through bolts. Slide bolt and button shall be "Tough coat black" finish. Thumb turn type not acceptable in order to meet Handicap codes.

 

3.   Strike and Keeper: 6” long extruded aluminum with clear anodized finish, equipped with rubber bumper, fastened to pilaster with vandal resistant theft resistant through bolts.

 

4.   Equip each door with sliding door latch and coat hook with bumper. Provide for emergency access.

 

      5.   Provide door pull and wall stop for outswinging doors. Equip handicap doors with inside and outside pulls.

 

F.     Wall and pilaster Brackets: 54” long, continuous Aluminum channel brackets.

 

 

2.04  FABRICATION

 

A.   Fabricate partitions from HDPE material with finished faces, free of saw marks, and all edges machined to .250 inch radius.

 

B.    Bevel corners and edges of cutouts.

 

C.    Doors, Panels, Pilasters and urinal screens:

 

1.      Thickness: 1 inch minimum,

2.      Door Width: 24 inches minimum.

3.      Door Width for physically disabled: door as front access to compartment: minimum 32 inch clear opening; for side access to compartment: minimum 34 inch clear opening.

4.      Door Height: 55 inches.

5.      Pilaster Height: 82 inches.

6.      Panel Height: 55 inches, mounted 14 inches above floor.

7.      Aluminum edging strips to be fastened to the bottom edge of all doors and panels.

D.    Urinal Screens:

 

1.      Thickness: 1 inch.

2.      Screen Width: 24 inches minimum.

3.      Screen Height: 42 inches mounted 14 inches above floor.

4.      Aluminum edging strips to be fastened to the bottom edge of all screens.

 

 

2.05 FINISHING:

 

A.     Color of HDPE: Poly-blending selection of Classics, Impressions, and eX Series.

 

B.     Stainless Steel Surfaces: No. 4 satin finish.

 

C.          Aluminum: Anodized clear natural color.

 

 

 

PART 3 - EXECUTION

 

3.01   EXAMINATION

 

A.   Verify correct spacing of and between plumbing fixtures.

 

            B.    Verify correct location of built-in framing, anchorage, and backing

 

 

3.02   INSTALLATION

 

A.    Install partitions secure, rigid, plumb, and level in accordance with manufacturer's instructions.

 

B.   Attach continuous wall brackets securely to walls using theft resistant stainless steel fasteners spaced maximum 13 inches O/C.

 

C.   Attach panels and pilasters to continuous brackets with vandal resistant through bolts.

 

D.  Locate head rail joints at pilaster center lines, and use end caps on exposed ends.

 

E.   Shoes anchored to floor with 1 1/2” #14 screws and plastic anchors. Pilaster secured within shoe with vandal resistant through bolt.

 

F.    Field touch-up of scratches or damaged finish will not be permitted. Replace   damaged or scratched materials with new materials.

 

 

 

 

3.03   ERECTION TOLERANCES

 

A.   Maximum Variation from True Position: 1/4 inch. Clearance at vertical edges of doors shall be uniform top to bottom and shall not exceed 1/4 inch.

 

B.        Maximum Variation From Plumb: 1/8 inch.

 

 

3.04  ADJUSTING

 

A.   Adjust and align hardware to uniform clearance at vertical edge of doors, not exceeding 1/4 inch.

 

B.      Adjust hinges to close doors when unlatched.

 

 3.05  CLEANING

 

A.    Clean finished surfaces under Section 01710.

 

B.     All surfaces shall be free of imperfections, scratch marks, blemishes or color variations.

 

C.     Remove and replace any components indicating evidence of imperfections.

 

  END OF SECTION