Go back
HOME | ABOUT US | CONTACT US
 
 
Guide Specification Guide Specification: Solid Plastic Lockers

SECTION-10500

 

 

Guide Specification: Lockers and Locker Benches

 

Comtec Industries.   (NOTE; some parts of this spec require custom information specific to your project)

 

Part 1 –GENERAL

 

1.1                 WORK OF THIS SECTION

 

  A.          The WORK of this Section includes providing solid plastic polymer resin lockers, locker room and wet

Gear benches, and all appurtenant work.

 

1.2           RELATED SECTIONS        

 

A.               The WORK of the following Section applies to the WORK of this Section.  Other Sections of the Specifications, not referenced below, shall also apply to the extent required for proper performance of this WORK.

 

1.                    Section 03300  Cast-in-Place Structural Concrete

2.                    Section 08710  Finish Hardware

 

1.3            CODES

 

A.               The WORK of this Section shall comply with the current editions of the following codes as adopted by the

Local code, if applicable.

1.                    Uniform Building Code

 

1.4           STANDARD SPECIFICATIONS

 

A.               Except as otherwise indicated, the current editions of the following apply to the WORK of this Section:

 

ASTM B 209                         Aluminum and Aluminum-Alloy Sheet and Plate

 

ASTM B 221                         Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes

 

ASTM B 241                         Aluminum and Aluminum-Alloy Seamless Pipe and Seamless Extruded Tube

 

1.5           SHOP DRAWINGS AND SAMPLES

 

A.               The following shall be submitted in compliance with Section 01300:

 

1.        Manufacturer’s catalogs containing technical data and installation instructions, shop drawings, and

       colors available.

 

2.        Samples of all the materials, finish, and color.  The samples shall be clearly marked to show the manufacturer’s name and product identification.  The manufacturer shall offer scale model and full set of color samples.

 

3.        Shop drawings for solid plastic locker benches, verifying all dimensions affecting the installation.  Lockers and benches shall be shown in detail, including method of installation, required fillers, trim, and accessories.  Locker numbering sequence information shall be provided if indicated.

 

 

1.6                 PRODUCT DELIVERY, STORAGE, AND HANDLING

 

A.               Delivery of Materials: Products shall be delivered in original, unbroken packages, containers, or bundles bearing the name of the manufacturer.

 

B.                Storage:  Products shall be carefully stored in a manner that will prevent damage and in an area that is protected from the elements.

 

C.                Solid plastic locker and benches shall not be delivered until the building is enclosed and ready for locker installation.

 

D.               Solid plastic locker and bench finishes, as well as adjacent surfaces and materials shall be protected from damage or marring during installation.

 

 

PART 2 – PRODUCTS

 

2.1           MATERIALS, GENERAL

 

A.               Solid Polyethylene Resin: High density, solid polymer resin formed under high pressure, with homogenous color throughout.  Provide material with seamless construction with edges eased and free from saw marks.  Colors as selected by the architect from manufacturer’s standards.

 

1.        Internal Sides, Shelves, Tops and Bottoms: Fabricated from high impact, high density, polyethylene (HDPE) 3/8" thick with homogenous natural white color throughout. Components shall have machined edges to accept assembly brackets.

 

2.        Doors, Door frames, Trim and End panels: Made from high density polyethylene (HDPE) Solid plastic 1/2" thick with homogeneous color throughout.

 

3.        Base; Lockers to be installed on a 4" high base. (bases are an optional item)

 

4.        Material Testing:  All solid plastic components shall resist deterioration and discoloration when subjected to the following chemicals and tested in accordance with corrosion-testing procedure established by the United States Plastic Corporation:

 

Acetic Acid 80%                          Caustic Soda                         Nicotine

Ammonium Phosphate                Cooper Chloride                   Lime Sulfur

Acetone                                         Chlorine Water                     Soaps                    

Ammonia Liquid                           Core Oils                                Potassium Bromide

Bleach 12%                                   Hydrochloric Acid 40%      Trisodium Phosphate

Brine                                               Hydrogen Peroxide 30%     Sodium Bicarbonate

Borax                                              Isopropyl Alcohol               Urea and Urine

Citric Acid                                     Lactic Acid 25%                   Vinegar

 

B.                Hardware:

 

1.        Latch:  Continuous slide latching mechanism that is capable of accepting a padlock and shall be securely fastened to the door.  Latch mechanism shall be ½” thick attached to the entire length of the door providing a continuous security latch.

 

2.        Hinges:  Continuous, integrated into the full length of the door and locker frame, made from heavy duty extruded aluminum with a powder coating to match the locker door and frame.

 

3.       Coat Hooks: Two prong type made from high impact plastic attached with theft resistant screws or rivets. One hook per opening in lockers 30” high or greater.

 

4.        Assembly brackets shall be full depth, width and height of the lockers. Brackets shall be made from PVC plastic and snap-fit assembled onto locker sides, backs and tops providing a continuous connection between components.

             

             

 

2.2           FABRICATION, GENERAL

 

A.                Construction:  Lockers shall be fabricated square, rigid, and without warp, with faces flat and free of dents, scratches or chips.

 

B.                 Solid plastic locker components shall snap together for easy assembly and shall provide a solid and secure construction. Adjacent lockers shall share a common side panel. Locker units shall be manufactured for assembly in a group of no more than five adjacent lockers.

 

C.                 Ventilation:  Slotted vents shall be provided in door face as follows:

 

1.        Single and Double-tier lockers shall have not less than 6-slotted openings top and bottom.

2.        Multi-tier lockers shall have not less than 6-slotted openings at top.

 

2.3           LOCKER ACCESSORIES

 

A.               Locking:  Lockers shall be fabricated to receive the following locking devices: (select one: Padlock, built in combination lock, coin lock)

 

B.                Number Plates: Number plates shall be manufacturer’s standard etched, embossed or stamped, number plates with numerals not less than 3/8 inch high fastened with theft resistant rivets. Lockers shall be numbered in sequence as directed by the architect.  Number plates shall be attached to face of each locker door, near the top, centered.

 

C.                Filler Panels: Filler panels shall be provided where indicated or required for a complete installation.  Panels shall be fabricated of not less than ½ inch solid plastic, and finished to match locker units.

 

 

2.4           LOCKER UNITS

 

A.               Locker units shall conform to the following requirements:

 

1.       Lockers shall consist of  (example: two-person, double tier lockers (sizes by each job need) for mounting on suitable curb, securely tied in banks as indicated; provided complete with number plates.  (Select type of curb material and show mounting height of base for lockers.)

 

2.5           MANUFACTURERS

 

A.               Products of the types indicated shall be as manufactured by one of the following (or approved equal by architect):

 

Tufftec Lockers by Comtec Industries; as Represented by Service Oriented Sales Ph (877) 767-4636

 

 

PART 3 – EXECUTION

 

3.1           LOCKERS

 

A.               Lockers shall be fastened to the structures in accordance with manufacturer’s printed recommendations and in conformance with the Uniform Building Code.  Frames and doors shall form a flush exterior when installed.  Lockers shall be plumb, level, rigid and securely fastened in banks.

 

B.                Fastenings shall be spaced not more than 48 inches on center, and applied through back-up reinforcing plates where necessary to avoid distortion.  Fasteners shall be concealed insofar as possible.

 

C.          Locker shall be jointed side by side with stainless steel theft resistant through bolts.

 

D.          Trim filler panels shall be installed where indicated. Using concealed fasteners to provide flush,

             hairline joints against adjacent surfaces.

 

 

3.2           LOCKER ROOM BENCHES (option, if needed)

 

A.               Bench tops to be 9 ½” wide and 1 ½” thick with all edges machined to a ¼” radius and all exposed edges free of saw marks.

 

B.                Solid polyethylene resin benches shall be installed in compliance with manufacturer’s instruction.

 

C.                Pedestal leg shall 2” Dia. and base to be 6” Dia. extruded anodized black aluminum.

 

D.               Secure to floor with stainless steel expansion anchors.

 

 

 

3.3           ADJUST AND CLEAN

 

A.               Doors and latches shall be adjusted to operate easily without binding.  Integral locking devices shall be verified as operating properly.

 

B.          Marred finishes shall be touched up, but units that cannot be restored to factory-finished appearance

                   Shall be replaced.  Only materials and procedures recommended or furnished by locker manufacturer shall

                   be used.

 

 

 
Copyright © 2003 Service Oriented Sales. All Rights Reserved